Advanced Search
Peng ZHU, Jajie LI, Wenxiang ZHANG, Yuliang ZHANG, Dapeng JIN, Ge LEI, Xuan WU, Yongcheng HE, Fengqin GUO, Mingtao KANG, Lin WANG. Design of CSNS Spectrometer T0 Signal Fan-out Equipment[J]. Nuclear Physics Review, 2020, 37(2): 199-208. DOI: 10.11804/NuclPhysRev.37.2020020
Citation: Peng ZHU, Jajie LI, Wenxiang ZHANG, Yuliang ZHANG, Dapeng JIN, Ge LEI, Xuan WU, Yongcheng HE, Fengqin GUO, Mingtao KANG, Lin WANG. Design of CSNS Spectrometer T0 Signal Fan-out Equipment[J]. Nuclear Physics Review, 2020, 37(2): 199-208. DOI: 10.11804/NuclPhysRev.37.2020020

Design of CSNS Spectrometer T0 Signal Fan-out Equipment

  • The high accuracy and reliability of the T0 signals is one of the most important prerequisites for Chinese Spallation Neutron Source(CSNS) target station spectrometer. Based on the CPLD(Complex Programmable Logic Device) and PMC(Peripheral Mezzanine Card) mother-daughter structure, T0 signal fan-out instruments were designed with a distributed architecture, including a special trigger signal receiver for the neutron chopper with 24 V level trigger. Before the first 1.6 GeV proton beam hits the target, the delay of all T0 signals have been adjusted correctly. These T0 signal fan-out instruments have superior flexibility, maintainability, scalability, which have been working for more than three years, and the whole T0 timing system has run smoothly and achieved high reliability. It has accumulated valuable experience for the higher demand of T0 signal fan-out instruments at the second phase spectrometer in the future.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return