Numerical Simulation on PSF of Pinhole Imaging System for Fast Neutron
doi: 10.11804/NuclPhysRev.25.02.139
- Received Date: 1900-01-01
- Rev Recd Date: 1900-01-01
- Publish Date: 2008-06-20
-
Key words:
- pinhole imaging /
- point spread function /
- Geant4
Abstract: The point spread function (PSF) of a pinhole imaging system for fast neutron has been studied through MonteCarlo method. The PSFs under different conditions have been obtained and analyzed by fitting the simulating data with Gauss function. As the results show, when the excursion is little, the PSF obtained by Gauss function fitting is feasible. A baffle will reduce the error and improve the spatial resolution remarkably.
Citation: | TANG Shi-biao, MA Qing-li, ZOU Ji-wei. Numerical Simulation on PSF of Pinhole Imaging System for Fast Neutron[J]. Nuclear Physics Review, 2008, 25(2): 139-143. doi: 10.11804/NuclPhysRev.25.02.139 |