Advanced Search
MA Li-zhen, HE Yuan, WANG Yue, YUAN Ping, HAN Shao-fei, YUAN You-jing, XIA Jia-wen. Design of Magnetic Septum of CSR[J]. Nuclear Physics Review, 2002, 19(4): 399-402. DOI: 10.11804/NuclPhysRev.19.04.399
Citation: MA Li-zhen, HE Yuan, WANG Yue, YUAN Ping, HAN Shao-fei, YUAN You-jing, XIA Jia-wen. Design of Magnetic Septum of CSR[J]. Nuclear Physics Review, 2002, 19(4): 399-402. DOI: 10.11804/NuclPhysRev.19.04.399

Design of Magnetic Septum of CSR

  • In order to satisfy the requirement of beam injection and extraction of CSR, four magnetic septums will be used in the accelerator. In the design, the shape of the lamination is optimized by 2-D magnetic field calculation. Also, in order to decrease the leakage field and obtain a satisfied field distribution, a special auxiliary coil and a shield iron plate are considered and as well as the construction of the septum leg is treated in a special way. As a result, the leakage field is almost...
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return