HIRFL辐照终端照射野均匀度与离子通量的关系
Relationship between Homogeneity of Irradiation Field and Ion Fluence at Irradiation Terminal of HIRFL
-
摘要: 采用固体核径迹探测器聚碳酸脂膜,测定了兰州重离子研究装置提供的55MeV/u40Ar和80MeV/u20Ne离子束经辐照终端束流均匀化扫描装置后照射野均匀度与离子通量之间的关系.结果表明:对于40Ar和20Ne离子束,离子通量小于1×106和2×107ions/cm2时,横向照射野均匀度缓Ne离子束照射慢增加;当离子通量分别介于1×106—1×107和2×107—1×108ions/cm2时,40Ar和20野均匀度逐渐增加;离子通量达到1×107和1×108ions/cm2时,40Ar和20Ne离子束照射野均匀度分别约为58%和61%.从而说明,辐照终端束流扫描装置对束流的均匀化程度目前并不能满足辐照生物效应、辐射育种和重离子治癌等研究工作的需要,须对其性能做进一步的提高. Using 55 MeV/u 40Ar and 80 MeV/u20Ne ion beams delivered by the Heavy Ion Research Facility at Lanzhou (HIRFL), the relationships between the irradiation homogeneities in irradiation fields generated by the beam scanning device located at the irradiation terminal of the HIRFL and ion fluence were measured respectively with 100 μm polycarbonate films by means of nuclear track detection. The results show that the homogeneity increases when the ion fluence are lower than ........Abstract: Using 55 MeV/u 40Ar and 80 MeV/u20Ne ion beams delivered by the Heavy Ion Research Facility at Lanzhou (HIRFL), the relationships between the irradiation homogeneities in irradiation fields generated by the beam scanning device located at the irradiation terminal of the HIRFL and ion fluence were measured respectively with 100 μm polycarbonate films by means of nuclear track detection. The results show that the homogeneity increases when the ion fluence are lower than ........