Study on Crystal Size and Detection Efficiency of HPGe Detector

doi: 10.11804/NuclPhysRev.30.01.058
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2013-03-20
  • The accurate shape of HPGe detector is needed in order to calculate its detection efficiency with Monte Carlo methods. In our calculation, the influence of the HPGe crystal size on efficiency has been investigated; the final crystal sizes were determined by comparison with experiments and were validated by the experimental efficiency obtained at several source-to-detector positions. The results show that when the crystal dimensions determined are used to calculate the detection efficiency in the energy range 122s1 332 keV, the relative deviations between simulated and most experimental results were within 5%. In addition, the relationship between detection efficiency and axial distance to detector was established.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1999) PDF downloads(514) Cited by()

Proportional views

Study on Crystal Size and Detection Efficiency of HPGe Detector

doi: 10.11804/NuclPhysRev.30.01.058

Abstract: The accurate shape of HPGe detector is needed in order to calculate its detection efficiency with Monte Carlo methods. In our calculation, the influence of the HPGe crystal size on efficiency has been investigated; the final crystal sizes were determined by comparison with experiments and were validated by the experimental efficiency obtained at several source-to-detector positions. The results show that when the crystal dimensions determined are used to calculate the detection efficiency in the energy range 122s1 332 keV, the relative deviations between simulated and most experimental results were within 5%. In addition, the relationship between detection efficiency and axial distance to detector was established.

MU Wan-jun, LI Mei, ZHONG Zheng-kun. Study on Crystal Size and Detection Efficiency of HPGe Detector[J]. Nuclear Physics Review, 2013, 30(1): 58-62. doi: 10.11804/NuclPhysRev.30.01.058
Citation: MU Wan-jun, LI Mei, ZHONG Zheng-kun. Study on Crystal Size and Detection Efficiency of HPGe Detector[J]. Nuclear Physics Review, 2013, 30(1): 58-62. doi: 10.11804/NuclPhysRev.30.01.058

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return