A New Calculation Method for Energy Deposition of Photon
doi: 10.11804/NuclPhysRev.28.01.097
- Received Date: 1900-01-01
- Rev Recd Date: 1900-01-01
- Publish Date: 2011-03-20
-
Key words:
- energy deposition /
- Xray /
- MonteCarlo simulation /
- radiotherapy
Abstract: Energy deposition distribution is very important to study radiotherapy or radioprotection. The *F8 method of MCNP program counts the energy loss of photon and electron together. Only real grid is allowed to *F8, so its computation efficiency is low. This paper gives a new calculation method for energy deposition of photon. Because the energy deposition of photon is accomplished by secondary electron, only electron is counted in the new method. The real collision of the electron is counted by the new method, whereas *F8 only counts the information of particle across the interface. Moreover, virtual grid is allowed in the new method. With real grid, the new method has the same precision and efficiency as *F8. If virtual grid is adopted by the new method, although the precision is slightly down, the efficiency is greatly increased.
Citation: | QIU You-heng, YING Yang-jun, WANG Min, CHEN Xing-liang. A New Calculation Method for Energy Deposition of Photon[J]. Nuclear Physics Review, 2011, 28(1): 97-102. doi: 10.11804/NuclPhysRev.28.01.097 |