Advanced Search
Volume 23 Issue 2
Jun.  2006
Turn off MathJax
Article Contents

SONG Gang, LI Guo-li, WU Ai-dong, CHEN Yi-xue, WU Yi-can, KONG Ling-ling, TANG Hong, WANG Zhi. Verification of RBM Dose Engine in Experiment Using Emulational Head Phantom[J]. Nuclear Physics Review, 2006, 23(2): 246-249. doi: 10.11804/NuclPhysRev.23.02.246
Citation: SONG Gang, LI Guo-li, WU Ai-dong, CHEN Yi-xue, WU Yi-can, KONG Ling-ling, TANG Hong, WANG Zhi. Verification of RBM Dose Engine in Experiment Using Emulational Head Phantom[J]. Nuclear Physics Review, 2006, 23(2): 246-249. doi: 10.11804/NuclPhysRev.23.02.246

Verification of RBM Dose Engine in Experiment Using Emulational Head Phantom

doi: 10.11804/NuclPhysRev.23.02.246
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2006-06-20
  • The dose distribution can be calculated by the Regular Beam Model (RBM) dose engine based on the accelerator parameters and the inhomogeneity data of the patient for the radiotherapy planning. In this paper, the newly-developed mixed Batho correction based RBM is introduced, and then the calculation results are compared with the measured ones using the head phantom. The results demonstrate that the RBM dose engine can be used as a kind of reliable fast dose calculation tool in the clinical treatment planning system.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1993) PDF downloads(673) Cited by()

Proportional views

Verification of RBM Dose Engine in Experiment Using Emulational Head Phantom

doi: 10.11804/NuclPhysRev.23.02.246

Abstract: The dose distribution can be calculated by the Regular Beam Model (RBM) dose engine based on the accelerator parameters and the inhomogeneity data of the patient for the radiotherapy planning. In this paper, the newly-developed mixed Batho correction based RBM is introduced, and then the calculation results are compared with the measured ones using the head phantom. The results demonstrate that the RBM dose engine can be used as a kind of reliable fast dose calculation tool in the clinical treatment planning system.

SONG Gang, LI Guo-li, WU Ai-dong, CHEN Yi-xue, WU Yi-can, KONG Ling-ling, TANG Hong, WANG Zhi. Verification of RBM Dose Engine in Experiment Using Emulational Head Phantom[J]. Nuclear Physics Review, 2006, 23(2): 246-249. doi: 10.11804/NuclPhysRev.23.02.246
Citation: SONG Gang, LI Guo-li, WU Ai-dong, CHEN Yi-xue, WU Yi-can, KONG Ling-ling, TANG Hong, WANG Zhi. Verification of RBM Dose Engine in Experiment Using Emulational Head Phantom[J]. Nuclear Physics Review, 2006, 23(2): 246-249. doi: 10.11804/NuclPhysRev.23.02.246

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return