Advanced Search

ZHANG Gui-ying, NI Bang-fa, LI li, TIAN Wei-zhi, WANG Ping-sheng, HUANG Dong-hui, ZHANG Lan-zhi, LIU Cun-xiong. Study on Personal Neutron Dosimetry bubble Detectors[J]. Nuclear Physics Review, 2005, 22(1): 100-102. doi: 10.11804/NuclPhysRev.22.01.100
Citation: ZHANG Gui-ying, NI Bang-fa, LI li, TIAN Wei-zhi, WANG Ping-sheng, HUANG Dong-hui, ZHANG Lan-zhi, LIU Cun-xiong. Study on Personal Neutron Dosimetry bubble Detectors[J]. Nuclear Physics Review, 2005, 22(1): 100-102. doi: 10.11804/NuclPhysRev.22.01.100

Study on Personal Neutron Dosimetry bubble Detectors

doi: 10.11804/NuclPhysRev.22.01.100
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2005-03-20
  • Neutron solid bubble detector was considered as a unique one for meeting the need of the personal neutron dosimeter recommended by International Committee of radiation protection,ICRP60.It has the flat response for neutron from low energy to high energy,and insensitive for gamma rays. In this work,superheated liquid drops were dispersed into a kind of soft polymer homogeneously.A personal neutron bubble dosimeter has been made,and the sensitivity reached to about 40bubbles/mrem.The principle and the processing procedure of bubble detector were also introduced in this paper.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1966) PDF downloads(827) Cited by()

Proportional views

Study on Personal Neutron Dosimetry bubble Detectors

doi: 10.11804/NuclPhysRev.22.01.100

Abstract: Neutron solid bubble detector was considered as a unique one for meeting the need of the personal neutron dosimeter recommended by International Committee of radiation protection,ICRP60.It has the flat response for neutron from low energy to high energy,and insensitive for gamma rays. In this work,superheated liquid drops were dispersed into a kind of soft polymer homogeneously.A personal neutron bubble dosimeter has been made,and the sensitivity reached to about 40bubbles/mrem.The principle and the processing procedure of bubble detector were also introduced in this paper.