Preliminary Experiment of Fast Neutron Imaging with Directfilm Method
doi: 10.11804/NuclPhysRev.22.01.079
- Received Date: 1900-01-01
- Rev Recd Date: 1900-01-01
- Publish Date: 2005-03-20
-
Key words:
- fast neutron radiography /
- fast neutron convertor /
- direct-film method
Abstract: A preliminary experiment is conducted with directfilm method under the condition that fast neutron is generated by the reaction of 9Be (d,n) on the Peking University 4.5 MV Van de Graff, whose energy is lower than 7 MeV.Basic characteristics of direct-film neutron radiography system is researched with the help of samples in different materials, different thickness and holes of different diameter. The fast neutron converter, which is vital for fast neutron imaging, is produced with the materials made in china. The result indicates that fast neutron converter can meet the requirment of fast neutron imaging; what's more, further research of fast neutron imaging can be conducted on the accelerator and neutron-generator in China.
Citation: | PEI Yu-yang, TANG Guo-you, GUO Zhi-yu, ZHANG Guo-hui. Preliminary Experiment of Fast Neutron Imaging with Directfilm Method[J]. Nuclear Physics Review, 2005, 22(1): 79-80. doi: 10.11804/NuclPhysRev.22.01.079 |