高级检索

留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments

帅鹏 涂小林 张玉虎 王猛 徐星 颜鑫亮 陈相成

帅鹏, 涂小林, 张玉虎, 王猛, 徐星, 颜鑫亮, 陈相成. Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments[J]. 原子核物理评论, 2016, 33(2): 173-179. doi: 10.11804/NuclPhysRev.33.02.173
引用本文: 帅鹏, 涂小林, 张玉虎, 王猛, 徐星, 颜鑫亮, 陈相成. Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments[J]. 原子核物理评论, 2016, 33(2): 173-179. doi: 10.11804/NuclPhysRev.33.02.173
SHUAI Peng, TU Xiaolin, ZHANG Yuhu, WANG Meng, XU Xing, YAN Xinliang, CHEN Xiangcheng. Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments[J]. Nuclear Physics Review, 2016, 33(2): 173-179. doi: 10.11804/NuclPhysRev.33.02.173
Citation: SHUAI Peng, TU Xiaolin, ZHANG Yuhu, WANG Meng, XU Xing, YAN Xinliang, CHEN Xiangcheng. Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments[J]. Nuclear Physics Review, 2016, 33(2): 173-179. doi: 10.11804/NuclPhysRev.33.02.173

Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments

doi: 10.11804/NuclPhysRev.33.02.173

Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments

  • 摘要:  The combination of in-flight fragment separator and the isochronous mass spectrometry(IMS) in storage rings have been proven to be a powerful tool for the precision mass measurements of shortlived exotic nuclei. In IMS, the mass-over-charge ratio is only related to the revolution period of stored ions, and the relative mass resolution can reach up to the order of 10−6. However, the instability of the magnetic field of storage ring deteriorates the resolution of revolution period, making it very difficult to distinguish the ions with very close mass-over-charge ratio via their revolution periods. To improve the resolution of revolution periods, a new method of weighted shift correction (WSC) has been developed to accurately correct the influence of the magnetic field instabilities in the isochronous mass measurements of 58Ni projectile fragments. By using the new method, the influence of unstable magnetic fields can be greatly reduced, and the mass resolution can be improved by a factor up to 1.7. Moreover, for the ions that still cannot be distinguished after correcting the magnetic field instabilities, we developed a new method of pulse height analysis for particle identification. By analyzing the mean pulse amplitude of each ion from the timing detector, the stored ions with close mass-over-charge ratios but different charge states such as 34Ar and 51Co can be identified, and thus the mass of 51Co can be determined. The charge-resolved IMS may be helpful in the future experiments of isochronous mass measurement even for N =Z nuclei.
  • 加载中
计量
  • 文章访问数:  912
  • HTML全文浏览量:  108
  • PDF下载量:  141
  • 被引次数: 0
出版历程
  • 刊出日期:  2016-06-20

Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments

doi: 10.11804/NuclPhysRev.33.02.173

摘要:  The combination of in-flight fragment separator and the isochronous mass spectrometry(IMS) in storage rings have been proven to be a powerful tool for the precision mass measurements of shortlived exotic nuclei. In IMS, the mass-over-charge ratio is only related to the revolution period of stored ions, and the relative mass resolution can reach up to the order of 10−6. However, the instability of the magnetic field of storage ring deteriorates the resolution of revolution period, making it very difficult to distinguish the ions with very close mass-over-charge ratio via their revolution periods. To improve the resolution of revolution periods, a new method of weighted shift correction (WSC) has been developed to accurately correct the influence of the magnetic field instabilities in the isochronous mass measurements of 58Ni projectile fragments. By using the new method, the influence of unstable magnetic fields can be greatly reduced, and the mass resolution can be improved by a factor up to 1.7. Moreover, for the ions that still cannot be distinguished after correcting the magnetic field instabilities, we developed a new method of pulse height analysis for particle identification. By analyzing the mean pulse amplitude of each ion from the timing detector, the stored ions with close mass-over-charge ratios but different charge states such as 34Ar and 51Co can be identified, and thus the mass of 51Co can be determined. The charge-resolved IMS may be helpful in the future experiments of isochronous mass measurement even for N =Z nuclei.

English Abstract

帅鹏, 涂小林, 张玉虎, 王猛, 徐星, 颜鑫亮, 陈相成. Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments[J]. 原子核物理评论, 2016, 33(2): 173-179. doi: 10.11804/NuclPhysRev.33.02.173
引用本文: 帅鹏, 涂小林, 张玉虎, 王猛, 徐星, 颜鑫亮, 陈相成. Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments[J]. 原子核物理评论, 2016, 33(2): 173-179. doi: 10.11804/NuclPhysRev.33.02.173
SHUAI Peng, TU Xiaolin, ZHANG Yuhu, WANG Meng, XU Xing, YAN Xinliang, CHEN Xiangcheng. Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments[J]. Nuclear Physics Review, 2016, 33(2): 173-179. doi: 10.11804/NuclPhysRev.33.02.173
Citation: SHUAI Peng, TU Xiaolin, ZHANG Yuhu, WANG Meng, XU Xing, YAN Xinliang, CHEN Xiangcheng. Technical Improvements in the Experiment of Isochronous Mass Measurement of 58Ni Projectile Fragments[J]. Nuclear Physics Review, 2016, 33(2): 173-179. doi: 10.11804/NuclPhysRev.33.02.173

目录

    /

    返回文章
    返回