MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam

Lamyae El Gonnouni Tarek El Bardouni Mariam Zoubair Mohamed Idaomar Abderrahmane Senhoo

Lamyae El Gonnouni, Tarek El Bardouni, Mariam Zoubair, Mohamed Idaomar, Abderrahmane Senhoo. MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. 原子核物理评论, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236
引用本文: Lamyae El Gonnouni, Tarek El Bardouni, Mariam Zoubair, Mohamed Idaomar, Abderrahmane Senhoo. MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. 原子核物理评论, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236
MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. Nuclear Physics Review, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236
Citation: MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. Nuclear Physics Review, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236

MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam

doi: 10.11804/NuclPhysRev.28.02.236

MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam

  • 摘要: In this paper, we have addressed the problem of the radiation transport with the Monte Carlo Nparticle(MCNP) code. This is a generalpurpose Monte Carlo tool designed to transport neutron, photon and electron in three dimensional geometries. To examine the performance of MCNP5 code in the field of external radiotherapy, we performed the modeling of an Electron Density phantom (EDP) irradiated by photons from 60Co source. The model was used to calculate the Percent Depth Dose (PDD) at different depths in an EDP. One field size for PDD has been examined. A 60Co photons source placed at 80 cm source to surface distance (SSD). The results of calculations were compared to TPS data obtained at National Institute of Oncology of Rabat.
  • 加载中
计量
  • 文章访问数:  1873
  • HTML全文浏览量:  43
  • PDF下载量:  535
  • 被引次数: 0
出版历程
  • 收稿日期:  1900-01-01
  • 修回日期:  1900-01-01
  • 刊出日期:  2011-06-20

MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam

doi: 10.11804/NuclPhysRev.28.02.236

摘要: In this paper, we have addressed the problem of the radiation transport with the Monte Carlo Nparticle(MCNP) code. This is a generalpurpose Monte Carlo tool designed to transport neutron, photon and electron in three dimensional geometries. To examine the performance of MCNP5 code in the field of external radiotherapy, we performed the modeling of an Electron Density phantom (EDP) irradiated by photons from 60Co source. The model was used to calculate the Percent Depth Dose (PDD) at different depths in an EDP. One field size for PDD has been examined. A 60Co photons source placed at 80 cm source to surface distance (SSD). The results of calculations were compared to TPS data obtained at National Institute of Oncology of Rabat.

English Abstract

Lamyae El Gonnouni, Tarek El Bardouni, Mariam Zoubair, Mohamed Idaomar, Abderrahmane Senhoo. MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. 原子核物理评论, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236
引用本文: Lamyae El Gonnouni, Tarek El Bardouni, Mariam Zoubair, Mohamed Idaomar, Abderrahmane Senhoo. MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. 原子核物理评论, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236
MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. Nuclear Physics Review, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236
Citation: MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. Nuclear Physics Review, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236

目录

    /

    返回文章
    返回