高级检索

留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering

LUO Wen XU Wang PAN Qiang-yan XU Yi FAN Gong-tao et al.

LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. 原子核物理评论, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115
引用本文: LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. 原子核物理评论, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115
LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. Nuclear Physics Review, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115
Citation: LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. Nuclear Physics Review, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115

A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering

doi: 10.11804/NuclPhysRev.26.S1.115

A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering

  • 摘要: A simple Xray spectrometer and a PCBased Data Acquisition System(DAS) have been developed newly in Shanghai Institute of Applied Physics(SINAP), Chinese Academy of Sciences(CAS) for the measurement of the Xray source generated using laser Compton scattering. The system consists of liquid nitrogen cooled high resolution Si(Li) detector, electronics and a DAQ. The Si(Li) detector was designed and made by Center of Advanced Instruments in SINAP, CAS, it allows us to measure Xrays with the energy up to 60 keV and the energy resolution(FWHM) of 184 eV at 5.9 keV. We measured the system uncertainty was 0.2 eV and time drifting of detector was 0.05% both at 5.9 keV. The DAQ was based on ObjectOriented software LabVIEW 7.1, it has data online analysis and original data saved functions.
  • 加载中
计量
  • 文章访问数:  1965
  • HTML全文浏览量:  95
  • PDF下载量:  543
  • 被引次数: 0
出版历程
  • 收稿日期:  1900-01-01
  • 修回日期:  1900-01-01
  • 刊出日期:  2020-05-11

A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering

doi: 10.11804/NuclPhysRev.26.S1.115

摘要: A simple Xray spectrometer and a PCBased Data Acquisition System(DAS) have been developed newly in Shanghai Institute of Applied Physics(SINAP), Chinese Academy of Sciences(CAS) for the measurement of the Xray source generated using laser Compton scattering. The system consists of liquid nitrogen cooled high resolution Si(Li) detector, electronics and a DAQ. The Si(Li) detector was designed and made by Center of Advanced Instruments in SINAP, CAS, it allows us to measure Xrays with the energy up to 60 keV and the energy resolution(FWHM) of 184 eV at 5.9 keV. We measured the system uncertainty was 0.2 eV and time drifting of detector was 0.05% both at 5.9 keV. The DAQ was based on ObjectOriented software LabVIEW 7.1, it has data online analysis and original data saved functions.

English Abstract

LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. 原子核物理评论, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115
引用本文: LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. 原子核物理评论, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115
LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. Nuclear Physics Review, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115
Citation: LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. Nuclear Physics Review, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115

目录

    /

    返回文章
    返回